STRATUS GC-2 Port
The STRATUS GC-2 Port portable monitoring system redefines the landscape of continuous gas analysis, delivering a new echelon of sensitivity. Designed with an advanced capillary column and a unique sensor, this model excels in precisely detecting volatile gases. Operating on the same foundational principle as its forerunner, the STRATUS GC-2 Port leverages the measurement of response times as gas molecules traverse from the capillary column to the specialized sensor.
The STRATUS GC-2 Port is engineered for mobility and agility, designed to swiftly adapt to various environments. Unlike its counterparts, this portable model doesn't accommodate router-based channel connections. However, it compensates with its exceptional portability, allowing swift installation in diverse spaces without the need for a router setup.
Integrating an evolved capillary column and sensor, the STRATUS GC-2 Port achieves an elevated level of gas detection precision. Its heightened sensitivity ensures the detection of even the most minute concentration changes with unparalleled accuracy. This advancement is particularly pivotal in scenarios where the presence of volatile gases necessitates swift and precise identification, enhancing safety and operational efficacy.
The STRATUS GC-2 Port heralds a new era of gas analysis by amalgamating sensitivity, mobility, and customization. Although it lacks certain connectivity features, its unparalleled sensitivity and portability make it an invaluable tool in situations demanding efficient and precise gas detection.
This model underscores ATHERO's commitment to advancing air quality monitoring solutions, providing industries with the crucial data required to ensure safer and more productive environments. The STRATUS GC-2 Port embodies our dedication to innovation, offering a portable solution that doesn't compromise on precision and performance.
Specifications
Detected gases |
• Methane (CH4) • Ethane (C2H6) • Propane (C3H8) • Isobutane (C4H10) • n-Butane (C4H10) • Isopentane (C5H12) • n-Pentane (C5H12) • Hexane (C6H14) • Heptane (C7H16) • Octane (C8H18) • Nonane (C9H20) • Decane (C10H22) • Hydrogen (H2) • Oxygen (O2) • Nitrogen (N2) • Carbon Dioxide (CO2) • Carbon Monoxide (CO) • Acetylene (C2H2) • Ethylene (C2H4) • Propylene (C3H6) * |
• Methane (CH4) • Ethane (C2H6) • Propane (C3H8) • Isobutane (C4H10) • n-Butane (C4H10) • Isopentane (C5H12) • n-Pentane (C5H12) • Hexane (C6H14) • Heptane (C7H16) • Octane (C8H18) • Nonane (C9H20) • Decane (C10H22) • Hydrogen (H2) • Oxygen (O2) • Nitrogen (N2) • Carbon Dioxide (CO2) • Carbon Monoxide (CO) • Acetylene (C2H2) • Ethylene (C2H4) • Propylene (C3H6) * |
• Methane (CH4) • Ethane (C2H6) • Propane (C3H8) • Isobutane (C4H10) • n-Butane (C4H10) • Isopentane (C5H12) • n-Pentane (C5H12) • Hexane (C6H14) • Heptane (C7H16) • Octane (C8H18) • Nonane (C9H20) • Decane (C10H22) • Acetylene (C2H2) • Ethylene (C2H4) • Propylene (C3H6) * |
• Methane (CH4) • Ethane (C2H6) • Propane (C3H8) • Isobutane (C4H10) • n-Butane (C4H10) • Isopentane (C5H12) • n-Pentane (C5H12) • Hexane (C6H14) • Heptane (C7H16) • Octane (C8H18) • Hydrogen (H2) • Oxygen (O2) • Nitrogen (N2) • Carbon Dioxide (CO2) • Carbon Monoxide (CO) • Acetylene (C2H2) • Ethylene (C2H4) • Propylene (C3H6) * |
• Methane (CH4) • Ethane (C2H6) • Propane (C3H8) • Isobutane (C4H10) • n-Butane (C4H10) • Isopentane (C5H12) • n-Pentane (C5H12) • Hexane (C6H14) • Heptane (C7H16) • Octane (C8H18) • Nonane (C9H20) • Decane (C10H22) • Acetylene (C2H2) • Ethylene (C2H4) • Propylene (C3H6) * |
---|---|---|---|---|---|
Measurement concentration | 50 to 1000 ppb | 50 to 1000 ppb | 50 to 1000 ppb | 50 to 1000 ppb | 50 to 1000 ppb |
Measurement step | 0,1 ppb | 0,1 ppb | 0,1 ppb | 0,1 ppb | 0,1 ppb |
Sampling injection | Automatic sampling from the tubular channel | Automatic and manual sampling from the tubular channel | Automatic sampling from the tubular channel | Manual sampling from the tubular channel | Manual sampling from the tubular channel |
Sampling gas amount | From 50 mL to 500 mL per minute | From 50 mL to 500 mL per minute | From 50 mL to 500 mL per minute | From 50 mL to 500 mL per minute | From 50 mL to 500 mL per minute |
Sampling frequency from one channel | Base value of 15 minutes ** | Base value of 15 minutes ** | Base value of 10 minutes ** | Base value of 15 minutes ** | Base value of 10 minutes ** |
Channel capacity | From 1 to 16 units *** | From 1 to 16 units *** | From 1 to 16 units *** | Not provided | Not provided |
Length of the route | Each channel up to 16.4 feet | Each channel up to 16.4 feet | Each channel up to 16.4 feet | Single sampling channel - 16 feet | Single sampling channel - 16 feet |
Column | CarboWax 30 m | CarboWax 30 m | CarboXen 30 m | CarboWax 30 m | CarboXen 30 m |
Sensor | PID | PID | Metal Oxide detector (Semiconductor gas sensor) | PID | Metal Oxide detector (Semiconductor gas sensor) |
Preconcentrator | Utilizes adsorbent material | Utilizes adsorbent material | Utilizes adsorbent material | Utilizes adsorbent material | Utilizes adsorbent material |
Additional Detectors | Real-time detector connection is available **** | Real-time detector connection is available **** | Real-time detector connection is available **** | Not provided | Not provided |
Additional Equipment | The system allows for the connection of a channel router and real-time detector **** | The system allows you to connect a modem, a channel router and a real-time detector **** | The system allows for the connection of a channel router and real-time detector **** | Not provided | Not provided |
Display | LED 10,1'', Tuch Screen | LED 10,1'', Tuch Screen | LED 10,1'', Tuch Screen | LED 9'', Tuch Screen | LED 9'', Tuch Screen |
Modem | Included in the basic kit | It is possible to connect as an additional device | Included in the basic kit | Connection is not provided | Connection is not provided |
Data Export Method | • USB interface • From the user's personal account database |
• USB interface • From the user's personal account database (when connecting the modem additionally) |
• USB interface • From the user's personal account database |
USB interface | USB interface |
Dimensions | 20'' x 16'' x 8'' | 18'' x 15'' x 8'' | 20'' x 16'' x 8'' | 18'' x 15'' x 7'' | 18'' x 15'' x 7'' |
Device Weight | 16.53 pounds (7.5 kg) | 15.43 pounds (7 kg) | 16.53 pounds (7.5 kg) | 15.5 pounds (7.03 kg) | 15.5 pounds (7.03 kg) |
Power Supply | 120 V, 50/60 Hz | 120 V, 50/60 Hz | 120 V, 50/60 Hz | 120 V, 50/60 Hz | 120 V, 50/60 Hz |
Power Consumption | Approx. 100 VA | Approx. 100 VA | Approx. 100 VA | Approx. 100 VA | Approx. 100 VA |
Operational Temperature Range | of 17 °F to 115 °F | of 17 °F to 115 °F | of 17 °F to 115 °F | of 17 °F to 115 °F | of 17 °F to 115 °F |
details | details | details | details |
* Please note that this list may vary depending on the specific configuration and settings of the gas analysis system
** It can be reduced during volatile gas detection
*** Multichannel capability requires additional router connection
**** It is not included in the main package. It can be added to the order as a separate item
Device Features
Cutting-Edge Analytical Capability
At the heart of the STRATUS GC-2 Port lies an advanced analytical capability, enabled by a highly sensitive capillary column. This innovative column enables the detection of a wide range of volatile gases, from the lightest to the heaviest molecules, all within the compact confines of the device. Remarkably, this portable model accelerates the analysis process, achieving conclusive results in a mere 15 minutes. Its versatility extends across an extensive concentration spectrum, exhibiting precision in detecting substances spanning from sub-ppb to concentrations reaching hundreds of ppm.
Effortless Automation
Drawing inspiration from its EX counterpart, the STRATUS GC-2 Port adheres to the fundamental principles of premium gas chromatographs found in laboratories. However, it introduces a groundbreaking element—a continuous operational cycle. This ingenious feature underpins uninterrupted 24/7 monitoring, revolutionizing the monitoring experience into a seamlessly automated endeavor. This advancement streamlines monitoring efforts and ensures prompt responses to dynamic air quality changes.
Adaptive VOC Detection
The STRATUS GC-2 Port distinguishes itself with a remarkable prowess in the detection of volatile organic compounds (VOCs). Equipped with a highly sensitive sensor, this device can accurately identify an array of compounds, spanning aromatic hydrocarbons, aliphatics, aldehydes, ketones, ethers, acids, and alcohols. The device's sensor is finely attuned to diverse functional groups, including halogens, oxygen, sulfur, nitrogen, and phosphorus. Notably, this comprehensive VOC detection excludes carbonoxides and carbonates. The STRATUS GC-2 Port stands as an indispensable tool for comprehensive VOC analysis, bolstering air quality monitoring across various domains.